Indirect Heating

Cabinet heaters


CABINET HEATERS
  • Catalytic Cabinet Heater No carbon monoxide produced
  • 3 Heat Settings up to 3.0 KW
  • Oxygen depletion and flame failure safety system
  • Child safe with lower touch temperatures
  • Additional child guard available
  • Butane fired using 15Kg Cylinder



PATIO HEATERS

Patio Heaters
  • 5m diameter Warming Area
  • 40,000 BTU of Heating
  • Propane Fired using 13 or 15Kg Cylinders
  • Available in stainless steel, black or green
  • Robust design free standing unit
  • Maximum Running Time 37 hrs (13Kg)
  • Ideal for heating outdoor hospitality and patio areas.

All of our products carry 12 month warranties ensuring total satisfaction for all our customers.

All our products are supported by years of experience in both manufacture and development.

They are built using the most up to date technology.



Professional site heaters


radiant Heater TS 3A radiant Heater HALL 1500 radiant Heater HALL 3000 radiant Heater HALL 3000 C
  • Radiant heating
  • Instant heat
  • No oxygen consumption
  • No air flow, no dust
  • No fumes, no odours, no humidiity
  • Low noise
  • 100% Efficiency
  • Variable heat settings
  • Strong and long lasting construction
fields of application
Close environments.
Agriculture, Construction, Garages, Shops, Houses, Offices, Cellars, Warehouses.
Recommended for painters, plasterers, tile setters, plumbers, etc.

Features TS 3AHALL 1500HALL 3000HALL 3000 C
Capacity:kW0.8- 1.6- 2.41.51.5-31.5-3
 Btu/h2,700- 8,2005,1005,100 - 10,2005,100 - 10,200
 Kcal/h690- 2,0701,2901,290 - 2,5801,290 - 2,580
Energy consumption:Amp.10.56.51313
Voltage:V/Hz230 - 240/50230 - 240/50230 - 240/50230 - 240/50
Packaging LxWxHt:cm38 x 24 x 4654 x 25 x 3255 x 34 x 6480 x 28 x 53
Net weight:kg7.44.81214
Gross weight:kg85.71315
Pallet:pcs36361216



COMMERCIAL / DOMESTIC ELECTRICAL HEATERS


ELECTRICAL HEATERS

HN20/2 2kw Convector Heater

  • Modern Styling.
  • Thermostat to control temperature.
  • Wall mount brackets included.
  • All models 42cmH x 61cmW x 17cmD
HN25V 2.5kw Convector Heater. Plus fan boost.


ELECTRICAL HEATERS

Infra Red Heaters

Infra 3s

  • Head output - 10200BTU (3kw)
  • Approx heated area - 2582ft3 (73m3)
  • Voltage - 230v or 110v




ELECTRICAL HEATERS

Infra 3c

  • Head output - 10200BTU (3kw)
  • Approx heated area - 2582ft3 (73m3)
  • Voltage - 230v or 110v


 

ELECTRIC FAN HEATERS

Electric heater
  • No oxygen consumption
  • No fumes, no odours, no humidiity
  • Low noise
  • 100% Efficiency
  • Motor with thermal protection
  • Stainless steel heating elements
  • Overheat thermostat
  • Built-in room thermostat
  • Variable heat, 4 position switch
  • Strong and long lasting construction
Fields of application
Close environments.
Agriculture, Construction, Garages, Shops, Houses, Offices, Cellars, Warehouses.
Recommended for painters, plasterers, tile setters, plumbers, etc.

For maximum drying efficiency use with a MASTER dehumidifier.

Features
B 2
B 3
B 5
B 9
B 15
B 22
Capacity:
kW
1-2
1.5-3
2.5-5
4.5-9
7.5-15
11-22
 
Btu/h
3,440 -
5,160 -
5,600 -
15,480 -
25,800 -
37,840 -
 
- 6,800
- 10,320
- 17,200
- 30,960
- 51,600
- 75,680
 
Kcal/h
860 -
1,290 -
2,150 -
3,870 -
6,450 -
9,460 -
 
- 1,720
- 2,580
- 4,300
- 7,740
- 12,900
- 18,920
Current consumption max:
Amp.
8.6
13
7.2
13
21.7
32
Voltage:
V/Hz
230 / 50
230 / 50
400 / 3-50
400 / 3-50
400 / 3-50
400 / 3-50
Air displacement:
m³/h
350
400
450
780
990
2,200
Thermostat control:
standard
standard
standard
standard
standard
standard
 
Packaging LxWxHt:
cm
22 x 24 x 43
29 x 28 x 43
29 x 36 x 41
34 x 44 x 54
38 x 48 x 53
52 x 58 x 64
Net weight:
kg
4
6
7
11
16
23
Gross weight:
kg
5
7
9
13
19
26
Pallet:
pcs
75
48
40
20
15
12


ELECTRICAL HEATERS

DE95

  • Head output - 68000BTU (20kw)
  • Approx heated area - 17211ft3 (487m3)
  • Voltage - 415v





INDIRECT FIRED MOBILE HEATING


indirect heating
  • Standard photocell cut off
  • Electronic flame control
  • Overheat and post-ventilation thermostats
  • Possible connection to an optional room thermostat
  • Stainless steel combustion chamber
  • Heat exchanger
  • Durable external painted finish
  • Strong and long lasting construction
  • Housing remains cool to the touch
  • Easy maintenance with external pump
  • High air flow

fields of application
Warehouses, workshops, building applications, greenhouses and animal housing.

Features  BV 170 E  BV 290 E BS 170E BS 290 E
Capacity:kW478165105
 Btu/h160.000280.000224.000360.000
 Kcal/h40.00070.00056.00090.300
Air displacement:m³/h1.8003.3001.8003.300
Fuel: kerosene / diesel oil
Oil consumption:kg/h3,86,83,95,1
Tank capacity:lt65105  
Electrical power:kW0,51,060,51,06
Energy consumption:Amp.2,34,62,34,6
Flue tube:mm150150--
Blast opening Ø:mm350400--
Thermostat control: possiblepossiblepossiblepossible
      
Net weight:kg721235887
Gross weight:kg8514478107

We can supply flue systems with all indirect heaters




High Output Indirect heaters

high output in direct heaters
  • Separate oil burner
  • Standard photocell cut off
  • Electronic flame control
  • Fan-limit thermostat with automatic reset
  • Limit thermostat with manual reset
  • Possible connection to an optional room thermostat
  • Summer-Winter switch for ventilation only
  • Standard Fuel pre-heating
  • Four way air-outlet panel
  • Possibility of canalization
  • Standard trolley
  • Stainless steel combustion chamber
  • Heat exchanger with high efficiency
  • Aluminium structural frame
  • External Painted Steel Double Plate
Features  BV 300 E BV 360 E BV 460 E BV 680 E
Capacity:kW81105134220
 Btu/h280.000360.000460.000760.000
 Kcal/h70.00090.000115.000190.000
Air displacement:m³/h5.0006.0008.00012.500
Fuel*: diesel oil diesel oil diesel oil diesel oil
Oil consumption:kg/h6,98,811,318,6
Tank capacity:lt----
Electrical power:kW0,550,751,12,2
Energy consumption:Amp.4,86,27,312,4
Flue tube:mm150150200200
Blast opening Ø:mm1x4501x5004x3004x300
Thermostat control: possiblepossiblepossiblepossible
      
Net weight:kg154160195360
Gross weight:kg168178215385



INDIRECT FIRED HEATERS


Indirect Fired HeatersBV 80 A BV 110E BV178 E BV 290E

Specifications
  • With heat exchanger and flue tube
  • Clean heat and high efficiency
  • Standard photocell cutoff
  • Easy to service and maintain with standard replacement parts
  • Housing remains cool to the touch
  • Combustion system is adjustable for clean combustion
  • Full automatic operation with room thermostat
  • High air displacement
  • Overheat switch protection


  BV 80 A BV 100E BV178 E BV 290E
CAPACITYkW
Btu/h.
23
80000
29
100000
47
160000
81
280000
AIR DISPLACEMENTm3/h12001500 1800 3300
FUEL CONSUMPTIONKg/h1.962.4 3.9 6.8
FUELdiesel oildiesel oil diesel oil diesel oil
TANK CAPACITYIt.41 65 65 105
ELECTRICAL POWERkW0.350.29 0.48 1.14
CURRENT TYPE ACAC AC AC
VOLTAGEV/Hz230 / 50 or 110 / 50230 / 50 or 110 / 50230 / 50 or 110 / 50230 / 50 or 110 / 50
DIMENSIONS LxWxHTcm118 x 51 x 92122 x 51 x 102136 x 51 x 102165 x 72 x 106
NET WEIGHTkg536672123
GROSS WEIGHT kg617985144
THERMOSTAT CONTROLoptionaloptionaloptionaloptional
FLUE TUBE Ømm150150150150
BLAST OPENING Ø mm300350350400




WASTE OIL FIRED MANUAL IGNITION ECONOMY HEATERS

Thermobile waste oil fired heaters can be operated using waste oil from diesel or petrol engines, gearboxes, transmissions, hydraulic systems, diesel oil or any combination of these. The following must not be used; solvents, thinners, petrochemical based oils, transformer oil or any oil above S.A.E. 90.Full combustion is achieved in a vaporising system and non burnable residue is retained in the burner pan. This system does not produce any unpleasant smell or smoke and the emissions from the flue stack are well below permitted contamination levels.

  • CLEAN, SOOT FREE COMBUSTION
  • CAN BURN PURE WASTEOIL OR MIXED WITH DIESEL
  • FAST RETURN ON INVESTMENT DUE TO FREE FUEL
  • HIGH EFFICIENCY
  • HEATER INCLUDES BUILT-IN-TANK, PUMB & CONTROLS
Technical Details
AT306
AT307
AT400
AT500
Capacity Btu/hr (1)
Max
80,000
80,000
112,000
170,000
Min
60,000
60,000
64,000
102,000
Fuel Consumption L/h (1)
Max
2
2
2.5
3.8
Min
3
3
4.3
6.2
Tank Capacity
Litres
50
50
55
55
Weight
Kg
67
84
130
175
Current
A
0.23
0.8
1
2
Flue Connection
0mm
130
130
130
180
Heated Airflow
m3/hr
-
1000
1000
3000
Max. space to be heated (2)
cu.ft
16,000
16,000
22,400
34,000

(1) Output depending on type of waste oil. (2) Depending on building insulation.

 

 
Width
Depth
Height
AT306
54cm (21")
98cm (39")
113cm (44")
AT307
54cm (21")
105cm (41")
127cm (50")
AT400
82cm (32")
110cm (43")
108cm (42")
AT500
82cm (32")
115cm (45")
128cm (50")

INFORMATION RELATING TO FLUE PIPING

The standard flue kit consists of:

Models AT306, AT307 & AT400
1 x T Piece complete with Draught Stabiliser
4 x 1m lengths of Flue Piping (150mm dia.) including change-over length.
1 x Terminal pipe

Model AT500
1 x T Piece complete with Draught Stabiliser
5 x 1m lengths of Flue Piping (200mm dia.)
including change-over length.
1 x Terminal pipe

Supports
Wall bands are available to suit the Flues and for wall fixed installation should be located at 3 metre centres. The bands give a 50mm clearance to the wall but extension brackets are also available with depths of 50mm, 100mm, 150mm, 200mm and 250mm. When combined with wall bands the extensions offer a wall clearance of 50mm to 300mm.

A Guy Wire fixing bracket is available to provide extra lateral support where the flue extends more than 1.5m above the last wall band, or for inter-connection with the roof flashing.

Roof Penetrations
Flat and angled flashings of sheet aluminium are available to provide suitable weather cover where the flue penetrates a roof. 'Dektite' silicone flashings are also available and highly recommended.

Storm collars of aluminium are also available and should be fitted to the pipe immediately above the flashings.

Terminations
To prevent leakage of rainwater into the pipe at joints which may be exposed above roof level, a change-over section is supplied in the flue kit. This section of pipe is provided with a male crimped coupling at each end and is designed for use where the flue passes through the roof: one end should be installed inside the building and one outside. any subsequent components are installed inverted, i.e. with the male coupling upwards and fitted and secured in the normal way.

Rain caps are not permitted with waste oil fired heaters. The terminal pipe is designed to deflect rain water down the outer section.

NB. All lengths and fittings are fabricated from 0.55mm Type 430 Stainless Steel.







| Heating Services inc. Hire Heat Services |
| Ray Lane Business Park, Kenlis Road, Barnacre, Preston, PR3 1GD. |
| TEL : 01995 601000 | FAX : 01995 600966 |